Focal Point (Legrand)
FTWLS. Twelve LED.
Configure
Add to project




RESOURCES
DESCRIPTION
Design
Low-profile rectilinear direct/indirect LED with frosted or MicroGlow lens
Performance
Angled LED boards direct light low and wide, enabling even distribution on the ceiling and wide fixture spacing
Gradient Optic diffuses lateral distribution to eliminate harsh lines on vertical surfaces
MicroGlow lens offers cutoff and brightness control to support comfortable environments
Five standard output levels, and Right Light capability to further target application goals
Selection of dimming drivers, including 1% dimming
Up to 108 lpw
L90 at 100,000 hours
5 year limited warranty
Application
Use in place of fluorescent to achieve energy savings and long life in classrooms, open offices, libraries and conference rooms.
Low-profile rectilinear direct/indirect LED with frosted or MicroGlow lens
Performance
Angled LED boards direct light low and wide, enabling even distribution on the ceiling and wide fixture spacing
Gradient Optic diffuses lateral distribution to eliminate harsh lines on vertical surfaces
MicroGlow lens offers cutoff and brightness control to support comfortable environments
Five standard output levels, and Right Light capability to further target application goals
Selection of dimming drivers, including 1% dimming
Up to 108 lpw
L90 at 100,000 hours
5 year limited warranty
Application
Use in place of fluorescent to achieve energy savings and long life in classrooms, open offices, libraries and conference rooms.
MORE DESCRIPTION
SPECIFICATIONS
- DimensionsW: 9.00"L: 4 Ft8 Ft12 Ft16'20'24'H: 1.57"
- Light SourceLED
- CCT/Color3000K3500K4000K
- CRI80
- Watt(Approx)6.3 W/Ft7.3 W/Ft8.5 W/Ft9.5 W/Ft10.8 W/Ft
- Lumens(Approx)750 Lm/Ft875 Lm/Ft1000 Lm/Ft1125 Lm/Ft1250 Lm/Ft
- OpticsIndirect/DirectBatwing Indirect/General Direct
- Adjustable
- DimmingDim to 3-10%Dim to 1%Step Dim0-10VDALILutron Hi-lume EcoSystem (LDE1)
- Controls/NetworkEthernetEnlightednLight®ENCELIUM®Wattstopper® DLMNX WirelessWaveLinxIntegral Sensor
- Power/VoltageIntegralPoEUNV 120-277V347V
- Integral EmergencyEM Integral
- Lumen Maintenance60000 h
- CertificatesUL/CUL
- EnvironmentDamp
- Mounting TypePendant